I’ve built a small office for myself with outlets all over the room. They are all on one circuit I’d like to protect them all with a single surge protector.

I imagine their should be some product similar to a GFI outlet that would protect itself and everything past it on the circuit. I could mount it next to my panel and run the wiring straight to it before continuing on to my office. But I can’t find such a device.

The two closest things I’ve found are a whole home surge protector which seems like overkill. And this outlet from Leviton which is a surge protector, but only for itself. It won’t protect anything else on the circuit.

I could obviously use a power bar with a built in surge protector but part of the idea of having a bunch of outlets around the room was to remove the need for a power bar and keep everything cleaner.

Does anyone know if what I’m imagining actually exists?

  • mvirts@lemmy.world
    link
    fedilink
    arrow-up
    1
    ·
    15 hours ago

    Hmmm power surges… that’s something I haven’t considered for a very long time.

    Anyone ever have something affected by a power surge?

    • hovercat@lemmy.blahaj.zone
      link
      fedilink
      English
      arrow-up
      2
      ·
      6 hours ago

      I had the amplifier for my bass shaker die from one, unfortunately. The company was super nice and sent me a refurbished one out of warranty though.

  • phrogpilot73@lemmy.world
    link
    fedilink
    arrow-up
    8
    ·
    1 day ago

    The Eaton TR5260 has a line/load side and their technical documentation says it provides downstream protection for the other outlets.

      • phrogpilot73@lemmy.world
        link
        fedilink
        arrow-up
        3
        ·
        edit-2
        1 day ago

        Only downside is it’s not a very robust surge protector. It’s 820 joules if I remember correctly. We have one installed for our all in one washer dryer and fridge. No issues so far.

        • Troz@sh.itjust.worksOP
          link
          fedilink
          arrow-up
          2
          ·
          1 day ago

          I saw that on the specs. It’s still better than nothing. Now I’ll have to see if it’s available in Canada. A quick search didn’t reveal anything but I’ll have more time to tonight.

  • confusedwiseman@lemmy.dbzer0.com
    link
    fedilink
    arrow-up
    7
    ·
    2 days ago

    I got one from my utility company. They installed it at the meter. It was about $400. Once it’s tripped, it will have to be replaced, but if something happens significant enough to trip that, I probably (hopefully) saved a lot of other large appliances and HVAC.

  • seathru@lemmy.sdf.org
    link
    fedilink
    English
    arrow-up
    4
    ·
    2 days ago

    Nothing stopping you from installing a “whole house” surge protector on that particular circuit. They aren’t that large or expensive.

  • HubertManne@moist.catsweat.com
    link
    fedilink
    arrow-up
    3
    ·
    2 days ago

    Just something to think about or look into but I was under the impression that home battery solutions include power conditioning which is sorta a better form of surge protetion. Even without solar panels or such if you have hourly pricing you could charge at lost cost times and run on battery power at peak cost times to save money and then also you get the benefit of being able to ignore power outages that are not to long.

        • mipadaitu@lemmy.world
          link
          fedilink
          English
          arrow-up
          2
          ·
          7 hours ago

          GFCI protects against a difference in current between the hot and neutral lines. This is intended to sense that the energy is going to the outlet, but returning through a different path, like through a meat bag full of mostly water.
          This is usually for wet locations like bathrooms and kitchens, to stop water from completing a circuit.

          A short circuit would be too much current going through the circuit, and would be stopped by a standard circuit breaker.
          These would be for every circuit, to protect against overloading the wires and outlets.

          An AFCI would detect if arcs are being generated in a line, like if there was a loose wire causing sparking somewhere. This would typically cause a very hot spot in the line which could cause a fire, but not necessarily cause a short circuit or an electrocution risk.
          These are usually only required in bedroom spaces to reduce the chance of a fire happening in the room you are sleeping in.

          Those are all different from a surge protector, which is intended to stop high voltage spikes, which typically occur from issues outside the house.
          These are typically used, in various types, to protect sensitive electronics and expensive appliances.

          Four different types of protection, for four different types of problems.