I’m cleaning this cabinet above the range/micro and noticed this mark on the back. I mostly keep cooking oils, vinegars, etc in here. Does this look serious?

Update: well it ain’t pretty, but it shouldn’t burn the house down. For anyone concerned, my electrician approves. Thank you all for your help today.

  • davidalso@lemmy.worldOP
    link
    fedilink
    arrow-up
    4
    ·
    9 months ago

    I am lucky. I had no idea this was going on back here. Here’s the back of the scorched cabinet.

    And here is my new cap job.

    I’m going to cover it with a plate and cut a hole in the melamine just as you suggested.

    The blue box is one of those kind that is supposed to latch into the drywall, but the melamine is cut too tight for that to have ever worked so it’s just busted out when I pulled on cabinet.

    • lettruthout@lemmy.world
      link
      fedilink
      English
      arrow-up
      2
      ·
      9 months ago

      Great! I’d also explore properly attaching the blue box to the drywall, then using a box extender to cover the space taken up by the melamine. This way the outlet and cover can be securely attached.

      • davidalso@lemmy.worldOP
        link
        fedilink
        arrow-up
        1
        ·
        9 months ago

        Thanks for the tips. That’s just what I’ll do. Do you think it’s important to mount it to the stud or will an old work box do?

        • lettruthout@lemmy.world
          link
          fedilink
          English
          arrow-up
          1
          ·
          edit-2
          9 months ago

          I see mounting to a stud as something useful if the outlet is expected to get a lot of use. The “wings” of old work box might possibly dig into the drywall and become loose. In this case the use level will be low, right? Besides, attaching to a stud is work intensive, and I believe that using an old work box like this is up to code. I’ve used them a number of times.

          EDIT: Also about the caps… I try to observe a “code plus” approach and wrap caps with friction tape (NOT the plastic electrician’s tape). That stuff will provide a little more protection for decades.

          • davidalso@lemmy.worldOP
            link
            fedilink
            arrow-up
            2
            ·
            9 months ago

            Oh interesting. I thought electrical tape was the only thing. I also like to do “code plus.” I’ll get some friction tape.

            Yeah once the micro is plugged in this never gets touched. And it’s on its own circuit.